Legionella bacteria are Gram-negative inhabitants of freshwater sources commonly found in free-living amoebae. Upon inhalation by humans, the bacteria also parasitize alveolar macrophages and lung epithelial cells. Legionella pneumophila is the species most frequently causing Legionnaires' disease, a severe form of pneumonia, which in many cases leads to an inhibition of lung function. One of the virulence determinants is the type II protein secretion system Lsp, which exports hydrolytic enzymes, like the Zn-metalloprotease, acid phosphatases, and phospholipases A. The actual virulence determinants transported by the type II system have not yet been found. Phospholipase activity has been characterized as a major virulence factor of bacteria such as Pseudomonas aeruginosa, Listeria monocytogenes and Yersinia enterocolitica
 
Legionnaires’ disease is caused by bacteria that belong to the family Legionellaceae. This family now includes 48 species and over 70 serogroups. Approximately half of these species have been implicated in human disease. Legionella pneumophila is responsible for approximately 90% of infections. Most cases are caused by L. pneumophila, serogroup 1. Legionella species are small (0.3 to 0.9 μm in width and approximately 2 μm in length) faintly staining Gram-negative rods with polar flagella.
 
Legionella organisms are readily found in natural aquatic bodies and some species have been recovered from soil. The organisms can survive in a wide range of conditions, including temperatures of 0 to 63o C, pH of 5.0 to 8.5, and dissolved oxygen concentrations of 0.2 to 15 ppm in water. Temperature is a critical determinant for Legionella proliferation. Colonization of hot water tanks is more likely if tank temperatures are between 40 and 50oC (104 to 122o F). Legionella and other microorganisms become attached to surfaces in an aquatic environment forming a biofilm.
 
 

For additional information, contact:
Pure Air Control Services

800-422-7873, ext. 802
 


[PRINTER FRIENDLY VERSION]
Request a FREE Copy of the Bioaerosol Guidelines
Employment Opportunities
Now Hiring

Microbiologists/
Aerobiologists:
Clearwater, FL
Atlanta, GA

Houston, TX
 
Industrial Hygienists: 
Clearwater, FL
Atlanta, GA
 
HVAC Remediation Techs.

Clearwater, FL

Sales Representative:
Clearwater, FL
Atlanta, GA

800-422-7873

IEQ Quiz of the Week

Which of the following is not an indication of poor cooling tower water chemistry control:

A. Anaerobic Bacterial Corrosion in chiller condenser heads and/or scaling on the tubes

B. Algae growth in the Cooling Tower basin

C.The presence of Legionella Bacteria in the Cooling Tower Basin

D.Clear water in the cooling tower basin

 [See Results]
Your IEQ Hotline! Toll Free 800-422-7873

Free Preliminary Phone Consultation Services Available. Call Now!
 
Free Subscription to The IEQ Review

First Name:

Last Name:

Email Address:

Company:


Add Remove

Tell A Friend About the IEQ Review!
Thank you for reading the IEQ REVIEW!
Published by: Pure Air Control Services
Copyright © 2006 Pure Air Control Services. All rights reserved.
TELL A FRIEND
View Archive
Powered by IMN