GE Fanuc Automation e-News

Friday, June 15, 2001 Issue 4   VOLUME 2 ISSUE 4  
HOME

TOPICS

Do U Know
What's Happening
Factory Outlet Sales
New Product Introduction
Who 2 Call?
PRONTO

CONTENTS

New High Density Analog Input Modules for VersaMax PLC and I/O Systems
Factory Outlet Sales Year 2001
New High Density Analog Output Modules for VersaMax PLC and I/O Systems
GE Fanuc TechForum
Competitor Ket Trade-In Discontinued!
New Members in GE Fanuc Singapore Office
Need Help?
APO Master Price

SUBSCRIBE

Enter your email address in the box below to receive an email each time we post a new issue of our newsletter:


 Add  Remove
 Send as HTML
 

ARCHIVE

Issue 3
May 23, 2001
Vol. 2 Issue 3
Issue 2
February 05, 2001
Vol. 2 Issue 2
Issue 1
January 19, 2001
Vol. 2 Issue 1
Issue 1
December 05, 2000
Vol. 1 Issue 1
New High Density Analog Output Modules for VersaMax PLC and I/O Systems
New Page 1

Summary

GE Fanuc is pleased to announce the introduction of two new VersaMax analog output modules. These modules can drive 10V unipolar and bi-polar analog outputs. Modules are available in 8 channel and 12 channel versions.

The modules are as follows:

  • IC200ALG325: 13 Bit Voltage, 8 Channel
  • IC200ALG327: 13 Bit Voltage, 12 Channel

Ordering Information

Catalog Number

Description

IC200ALG325

13 Bit Voltage, 8 Channel Analog Output

IC200ALG327

13 Bit Voltage, 12 Channel Analog Output

Related Documentation

GFK-1504 VersaMax Modules, Power Supplies, and Carriers User’s Manual

IC200ALG325: 13 Bit Voltage, 8 Channel Analog Output

Analog output module IC200ALG325 provides eight analog voltage outputs. The output range can be either –10VDC to +10VDC (bipolar) or 0V to +10VDC (unipolar).

An external 24V power supply is required for the outputs.

Intelligent processing for this module is performed by the CPU or Network Interface Unit. The module receives 8 words of analog output data.

Module Specifications

Module Characteristics

Channels

8 single-ended, one group

Isolation:

User input to logic (optical) and to frame ground

Group to group

Channel to channel

 

250VAC continuous; 1500VAC for 1 minute

Not applicable

None

LED indicators

FLD PWR LED indicates field power is present
OK LED indicates backplane power is present

Backplane current consumption

5V output: 50 mA maximum

External power supply:
Range
Current consumption


+18 to +30VDC (including ripple)
102mA maximum

Thermal derating

None

Configuration parameters

Range, output default

Diagnostics

Loss of User Side Power

 

Output Characteristics

Output voltage

-10.24 to +10.24VDC (bipolar range)

0 to +10.24VDC (unipolar range)

Load characteristics:
Resistive
Capacitive


5000 Ohms minimum
1.0m F maximum

Accuracy at:
25 degrees C


0 to 60 degrees C


+/- 0.3% typical of full scale, +/- 0.5% maximum of full scale

+/-1% maximum of full scale

Resolution

1.25mV = 4 counts

Update rate

10 mSec maximum

Channel-to-channel crosstalk rejection

70dB minimum

Output default

Hold Last State (default)
0V (configurable)

 

IC200ALG327: 13 Bit Voltage, 12 Channel Analog Output

Analog output module IC200ALG327 provides twelve analog voltage outputs. The output range can be either –10VDC to +10VDC (bipolar) or 0V to +10VDC (unipolar).

An external 24V power supply is required for the outputs.

Intelligent processing for this module is performed by the CPU or Network Interface Unit. The module receives 12 words of analog output data.

Module Specifications

Module Characteristics

Channels

12 single-ended, one group

Isolation:

User input to logic (optical) and to frame ground

Group to group

Channel to channel

 

250VAC continuous; 1500VAC for 1 minute

Not applicable

None

LED indicators

FLD PWR LED indicates field power is present
OK LED indicates backplane power is present

Backplane current consumption

5V output: 50mA maximum

External power supply:
Range
Current consumption


+18 to +30VDC (including ripple)
112mA maximum

Thermal derating

None

Configuration parameters

Range, output default

Diagnostics

Loss of User Side Power

 

Output Characteristics

Output voltage

-10.24 to +10.24VDC (bipolar range)

0 to +10.24VDC (unipolar range)

Load characteristics:
Resistive
Capacitive


5000 Ohms minimum
1.0m F maximum

Accuracy:
at 25 degrees C

0 to 60 degrees C


+/- 0.3% typical of full scale, +/- 0.5% maximum of full scale

+/-1% maximum of full scale

Resolution

1.25mV = 4 counts

Update rate

15 mSec maximum

Channel-to-channel crosstalk rejection

70dB minimum

Output default

Hold Last State (default)
0V (configurable)

 

VersaMax is a trademark of GE Fanuc Automation North America, Inc.

Joanne Lim


[PRINTER FRIENDLY VERSION]
Published by GE Fanuc
Copyright © 2001 GE Fanuc Automation Asia Pacific Pte Ltd. All rights reserved.
Information Centers: GE Fanuc Asia Pacific 65-566-4918 Internet Access: Http://gefanuc

Internet Access: Http://gefanuc.com, please tell us your feedback.

TELL A FRIEND
Powered by iMakeNews.com