VersaPoint I/O
by Joanne Lim
VersaPoint™ I/O
Summary
GE Fanuc is pleased to announce the introduction of VersaPoint™ I/O. VersaPoint is a modular I/O system that allows the user to add I/O in 1, 2, 4, 8, or 16 point increments. These low point counts afford users the flexibility to specify the exact amount of I/O needed for each application and appeal to application in which a wide variety of I/O is required, but cost is critical and space is limited.
VersaPoint eBinder
The VersaPoint launch material is now available through the eBinder. This enables you to access information for local printing or customization on the material printed. Just drop us an email and we will forward the eBinder to you. What's included:
- Product Bulletins
- Pricing Bulletins
- Press Release
- Collateral
- Presentation (available in Marketing CD Volume 4)
- Competitive Comparison
- FAQ
- VersaPoint I/O Application Guide
Features / Benefits
To address the growing customer need for smaller, more easily customized I/O drops, GE Fanuc has created a new product family that fully embraces open system designs. Using the design for Six Sigma process, we conducted extensive research to determine customer requirements for this new system. The result is VersaPoint I/O.
Modular and Scaleable: The defining attributes of the VersaPoint I/O system are modularity and scalability. Contrary to traditional I/O structures that require I/O to be installed in multiples of 8, 16, or 32 point modules, VersaPoint provides the ultimate in flexibility with modules designed for as few as 1, 2, or 4 points. When these are coupled with VersaPoint’s 8 and 16 point modules, users are able to install precisely the number and mix of I/O required for each application. This flexibility allows OEMs and end users alike to save money and panel space when building their automation systems.
- Snap-together modules: VersaPoint modules snap together on a 35mm x 7.5mm DIN rail, eliminating the need for a rack and cable interconnections.
- Up to 1008 points of local I/O supported: Each Network Interface Unit supports a maximum of 63 I/O modules.
- Small footprint: In addition to the space savings afforded by selecting only the I/O required for a system, the VersaPoint modules themselves are also quite small – many of them are only 12mm wide!
Easy to Use: VersaPoint I/O was designed with quick installation and low mean time to repair in mind.
- No tools: The installation of an I/O module is a simple two-step process: First, engage the I/O module with the adjacent I/O module or Network Interface Unit and slide it towards the DIN rail until it snaps securely in place. Second, attach the wiring terminal block, snapping it into place and locking the I/O module onto the DIN rail.
- Automatic addressing of I/O: I/O modules connected to a Network Interface Unit have their reference addressing assigned automatically upon power up -- no programming required.
- Removable terminal strips: VersaPoint I/O’s removable termination strips simplify system installation and reduce mean time to repair. Designing a system in this fashion has allowed GE Fanuc to achieve the delicate balance between maximized maintainability, modularity, and minimized cost. This functionality combined with VersaPoint’s ability to pinpoint faults means decreased down-time.
Wide Range of Discrete I/O: VersaMax® I/O is available in a wide range of discrete modules.
- 12 modules: 5 discrete input modules, and 7 discrete output modules.
- 2, 4, 8, and 16 point densities: Modules are available in a variety of point densities, enabling you to save cost and space.
Analog I/O Options: A wide variety of analog I/O options are also available.
- 6 modules: 3 analog input modules, and 3 analog output modules.
- Thermocouple and RTD inputs: VersaPoint offers a Thermocouple input module and an RTD input module. Each module supports 2 channels and offers 16 bit resolution.
- 1 and 2 channel analog: Standard analog I/O modules are available in 1 and 2 channels.
- Support for 2, 3, and 4 wire devices: Unlike traditional I/O systems which require additional terminal strips to accommodate 3 and 4 wire devices, VersaPoint modules are designed to support these devices out of the box.
Variety of Network Interfaces: Network Interface Units (NIUs) provide the interface for VersaPoint I/O modules to connect to a network. Together, the NIU and its modules form an I/O station capable of providing up to 1008 points of I/O. The system host can be any device capable of operating as a bus master. The Network Interface Unit installs on a DIN rail adjacent to the I/O modules. The following NIUs are available *
:
*
GE Fanuc is also in the process of developing NIUs for Ethernet and Genius.
Intuitive Diagnostics:
- Electronic short circuit protection on all DC output modules.
- Each VersaPoint I/O module provides status indication via a diagnostics LED.
- The Network Interface Units include LEDs to display network status, fault type, and power.
- NIU Fault information is available via the network, including fault type and fault location.
Ordering Information
|
Catalog # |
Description |
|
Discrete Input Modules |
|
IC220MDL641 |
Input 24VDC Positive Logic 2PT (Requires 1 IC220TBK082) |
|
IC220MDL642 |
Input 24VDC Positive Logic 4PT (Requires 1 IC220TBK122) |
|
*
IC220MDL643 |
Input 24VDC Positive Logic 8PT (Requires 4 IC220TBK082) |
|
*
IC220MDL644 |
Input 24VDC Positive Logic 16PT (Requires 4 IC220TBK122) |
|
*
IC220MDL661 |
Input 24VDC Negative Logic 2PT (Requires 1 IC220TBK082) |
|
Discrete Output Modules |
|
IC220MDL721 |
Output 24VDC Positive Logic 2.0A 2PT (Requires 1 IC220TBK082) |
|
*
IC220MDL751 |
Output 24VDC Positive Logic 0.5A 2PT (Requires 1 IC220TBK082) |
|
IC220MDL752 |
Output 24VDC Positive Logic 0.5A 4PT (Requires 1 IC220TBK123) |
|
*
IC220MDL753 |
Output 24VDC Positive Logic 0.5A 8PT (Requires 4 IC220TBK082) |
|
*
IC220MDL754 |
Output 24VDC Positive Logic 0.5A 16PT (Requires 4 IC220TBK123) |
|
*
IC220MDL761 |
Output 24VDC Negative Logic 0.5A 2PT (Requires 1 IC220TBK082) |
|
Relay Output Modules |
|
IC220MDL930 |
Output Relay 3.0A 1PT (Requires 1 IC220TBK085) |
|
Analog Input Modules |
|
IC220ALG220 |
Analog In 15 Bit Voltage/Current 2CH (Requires 1 IC220TBK061) |
|
*
IC220ALG620 |
Analog In 16 Bit RTD 2CH (Requires 1 IC220TBK061) |
|
*
IC220ALG630 |
Analog In 16 Bit Thermocouple 2CH (Requires 1 IC220TBK061) |
|
Analog Output Modules |
|
IC220ALG320 |
Analog Out 16 Bit Voltage/Current 1CH (Requires 1 IC220TBK203) |
|
IC220ALG321 |
Analog Out 16 Bit Voltage 1CH (Requires 1 IC220TBK061) |
|
*
IC220ALG322 |
Analog Out 13 Bit Voltage 2CH (Requires 1 IC220TBK061) |
|
I/O Terminal Strips |
|
IC220TBK061 |
I/O Terminal Strip w/Shield, 6 Position Spring Style, Qty 5 |
|
IC220TBK082 |
I/O Terminal Strip, 8 Position Spring Style w/Color, Qty 10 |
|
IC220TBK085 |
I/O Terminal Strip, 8 Position Spring Style, Relay, Qty 10 |
|
IC220TBK087 |
Power Terminal Strip, 8 Position Spring Style w/Color, Qty 10
|
|
IC220TBK122 |
I/O Terminal Strip, 12 Position Spring Style w/Color, Input, Qty 10 |
|
IC220TBK123 |
I/O Terminal Strip, 12 Position Spring Style w/Color, Output, Qty 10 |
|
IC220TBK201 |
Terminal Strip Set, Spring Style, NIU |
|
IC220TBK203 |
Terminal Strip Set, Spring Style, Analog Out |
|
Network Interface Units |
|
IC220PBI001 |
Profibus-DP Network Interface Unit (Requires 1 IC220TBK087) |
|
IC220DBI001 |
DeviceNet Network Interface Unit (Requires 1 IC220TBK201) |
|
Power Supplies |
|
IC220PWR001 |
Power Terminal, 24VDC (Requires 1 IC220TBK087) |
|
*
IC220PWR002 |
Power Terminal, Fused, 24VDC (Requires 1 IC220TBK087) |
|
*
IC220PWR003 |
Power Terminal, Fused w/Diagnostics, 24VDC (Requires 1 IC220TBK087) |
|
IC220PWR011 |
Segment Terminal, 24VDC (Requires 1 IC220TBK087) |
|
*
IC220PWR012 |
Segment Terminal, Fused, 24VDC (Requires 1 IC220TBK087) |
|
*
IC220PWR013 |
Segment Terminal, Fused w/Diagnostics, 24VDC (Requires 1 IC220TBK087) |
|
*
IC220PWR014 |
Segment Terminal, Eletronically Fused, 24VDC (Requires 1 IC220TBK087) |
|
Accessories |
|
IC220ACC001 |
Module Labels Narrow Qty 10 |
|
IC220ACC002 |
Module Labels Wide Qty 10 |
|
IC220ACC003 |
Point Labels Numbered 1-100 Qty 10 |
|
IC220ACC004 |
Point Labels Blank Qty 1000 |
|
IC220ACC005 |
Module Keying tabs Qty 100 |
|
Demo Case |
|
IC200DEM001 |
VersaPoint Demo Case, DeviceNet NIU |
|
IC200DEM002 |
VersaPoint Demo Case, Profibus NIU |
|
IC200DEM011 |
VersaPoint Static Demo, DeviceNet NIU |
|
IC200DEM012 |
VersaPoint Static Demo, Profibus NIU |
*
Target availability is 2Q 2001
Target Customers/Applications
As a universal I/O system, VersaPoint is ideal as an I/O structure for host controllers that communicate on DeviceNet, Profibus-DP and soon, Genius® bus and Ethernet. These controllers include PLCs, PC Control, and DCS systems. The flexibility, performance, and cost-effectiveness of VersaPoint I/O make it particularly attractive to OEMs. The features built into VersaPoint are also well suited for customers in the general machinery, manufacturing, semiconductor, and water/wastewater industries.
Related Documentation
|
GFK# |
Description |
|
GFK-1911 |
VersaPoint™ I/O System, Profibus-DP User’s Manual |
|
GFK-1912 |
VersaPoint™ I/O System, Devicenet User’s Manual |
Genius and VERSAMAX are registered trademarks, and VersaPoint is a trademark of GE Fanuc Automation North America, Inc. DeviceNet is a trademark of the Open DeviceNet Vendor Association, Inc. All other trademarks and registered trademarks are the property of their respective owners.
[PRINTER FRIENDLY VERSION]
|